diff --git a/data/driver.list.in b/data/driver.list.in index aaad8399a4..cc7ebe0e28 100644 --- a/data/driver.list.in +++ b/data/driver.list.in @@ -513,22 +513,37 @@ "LDLC" "ups" "2" "UPS-1200D" "" "blazer_usb langid_fix=0x4095" -"Legrand" "ups" "4" "DHEA 1000" "" "metasys" -"Legrand" "ups" "4" "DHEA 1500" "" "metasys" -"Legrand" "ups" "2" "Keor Multiplug" "" "nutdrv_qx" -"Legrand" "ups" "2" "Keor PDU" "" "usbhid-ups" -"Legrand" "ups" "2" "Keor SP" "" "usbhid-ups" -"Legrand" "ups" "4" "WHAD 800" "" "metasys" -"Legrand" "ups" "4" "WHAD 1000" "" "metasys" -"Legrand" "ups" "4" "WHAD 1250" "" "metasys" -"Legrand" "ups" "4" "WHAD 1500" "" "metasys" -"Legrand" "ups" "4" "WHAD 2000" "" "metasys" -"Legrand" "ups" "4" "WHAD 2500" "" "metasys" -"Legrand" "ups" "4" "WHAD CAB 1250" "" "metasys" -"Legrand" "ups" "4" "WHAD CAB 2500" "" "metasys" -"Legrand" "ups" "4" "WHAD HE 800" "" "metasys" -"Legrand" "ups" "4" "WHAD HE 1000" "" "metasys" -"Legrand" "ups" "4" "WHAD HE 1500" "" "metasys" +"Legrand" "ups" "2" "Keor SPX" "USB" "nutdrv_qx" +"Legrand" "ups" "2" "Keor Multiplug" "USB" "nutdrv_qx" +"Legrand" "ups" "2" "Daker DK / DK+" "Serial" "nutdrv_qx" +"Legrand" "ups" "2" "Daker DK / DK+" "USB" "nutdrv_qx" +"Legrand" "ups" "2" "Niky / Niky S" "Serial" "nutdrv_qx" +"Legrand" "ups" "2" "Niky / Niky S" "USB" "nutdrv_qx" +"Legrand" "ups" "2" "Keor LP/S/Line RT" "Serial" "nutdrv_qx" +"Legrand" "ups" "2" "Keor S/Line RT" "USB" "nutdrv_qx" +"Legrand" "ups" "2" "Keor PDU" "USB" "usbhid-ups" +"Legrand" "ups" "2" "Keor SP" "USB" "usbhid-ups" +"Legrand" "ups" "4" "DHEA 1000" "Serial" "metasys" +"Legrand" "ups" "4" "DHEA 1500" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD 800" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD 1000" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD 1250" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD 1500" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD 2000" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD 2500" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD CAB 1250" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD CAB 2500" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD HE 800" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD HE 1000" "Serial" "metasys" +"Legrand" "ups" "4" "WHAD HE 1500" "Serial" "metasys" +"Legrand" "ups" "4" "Megaline 1250" "Serial" "metasys" +"Legrand" "ups" "4" "Megaline 2500" "Serial" "metasys" +"Legrand" "ups" "4" "Megaline 3750" "Serial" "metasys" +"Legrand" "ups" "4" "Megaline 5000" "Serial" "metasys" +"Legrand" "ups" "4" "Megaline 6250" "Serial" "metasys" +"Legrand" "ups" "4" "Megaline 7500" "Serial" "metasys" +"Legrand" "ups" "4" "Megaline 8750" "Serial" "metasys" +"Legrand" "ups" "4" "Megaline 10000" "Serial" "metasys" "Lestar" "ups" "2" "MD-800E" "" "blazer_ser" @@ -587,14 +602,7 @@ "Meta System" "ups" "4" "ally HF 1600" "" "metasys" "Meta System" "ups" "4" "ally HF 2000" "" "metasys" "Meta System" "ups" "4" "ally HF 2500" "" "metasys" -"Meta System" "ups" "4" "Megaline 1250" "" "metasys" -"Meta System" "ups" "4" "Megaline 2500" "" "metasys" -"Meta System" "ups" "4" "Megaline 3750" "" "metasys" -"Meta System" "ups" "4" "Megaline 5000" "" "metasys" -"Meta System" "ups" "4" "Megaline 6250" "" "metasys" -"Meta System" "ups" "4" "Megaline 7500" "" "metasys" -"Meta System" "ups" "4" "Megaline 8750" "" "metasys" -"Meta System" "ups" "4" "Megaline 10000" "" "metasys" + "MGE Office Protection Systems" "ups" "5" "Protection Center 500/675 VA" "USB" "usbhid-ups" "MGE Office Protection Systems" "ups" "5" "Protection Station 500/650/800 VA" "USB" "usbhid-ups"