OpenMS Glossary
==============

A glossary of common terms used throughout OpenMS documentation.

```{glossary}
LC-MS
[Liquid Chromatography(LC)](introduction.md#liquid-chromatography-lc) and [Mass Spectrometry(MS)](introduction.md#mass-spectrometry).

Peptides
A short chain of amino acids.

Octadecyl(C18)
An alkyl radical C~18~H~37~ derived from an octadecane by removal of one hydrogen atom.

Mass
Mass is a measure of the amount of matter that an object contains. In comparison to often used term weight, which is
a measure of the force of gravity on that object.

Ion
Any {term}`atom` or group of atoms that bears one or more positive or negative electrical charges. Positively charged are
cations, negavtively charged anions.

Atom
An atom is the smallest unit of ordinary matter that forms a chemical element.

Electrospray ionization
A technique used in mass spectrometry to produce ions using an electrospray in which a high voltage is applied to a
liquid to create an {term}`aerosol`.

Aerosol
An aerosol is a suspension of fine solid particles or liquid droplets in air or another gas.

Time-of-flight (TOF)
A measurement of the time taken by an object, particle of wave (be it acoustic, electromagnetic, e.t.c) to travel a
distance through a medium.

Quadrupole mass filters
A mass filter allowing one mass channel at a time to reach the detector as the mass range is scanned.

Orbitrap analyzers
In mass spectrometry, an ion trap mass analyzer consisting of an outer barrel-like electrode and a coaxial inner
spindle-like electrode that traps ions in an orbital motion around the spindle.
A high resoltion mass spectrometry analyzer.

MS(1)
First stage to get a spectra. A sample is injected into the mass spectrometer, ionized, accelerated and analyzed by
mass spectrometry.

MS(2)
Ions from MS1 spectra are then selectively fragmented and analyzed by a second stage of mass spectrometry (MS2) to
generate the spectra for the ion fragments.

MS/MS
Tandem mass spectrometry, MS^2^, a technique where two or more mass analyzers are coupled together using an additional
reaction step to increase their abilities to analyse chemical samples.

Collision-induced dissociation (CID)
A mass spectrometry technique to induce fragmentation of selected ions in the gas phase. Also known as Collision
induced dissociation.

```
6 changes: 6 additions & 0 deletions docs/index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -85,6 +85,12 @@ Contents

downloads.md

.. toctree::
:maxdepth: 2
:caption: Glossary

glossary.md

.. toctree::
:maxdepth: 2
:caption: Contact Us
Expand Down
47 changes: 24 additions & 23 deletions docs/introduction.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,7 +2,7 @@ Introduction
============

[OpenMS](http://www.openms.org/)
is an open-source software C++ library for LC-MS data management and
is an open-source software C++ library for {term}`LC-MS` data management and
analyses. It offers an infrastructure for rapid development of mass
spectrometry related software. OpenMS is free software available under the
three clause BSD license and runs under Windows, macOS, and Linux.
Expand Down Expand Up @@ -31,59 +31,60 @@ or basic research.
LC aims to reduce the complexity of the measured sample by separating analytes based on their physicochemical properties.
Separating analytes in time ensures that a manageable amount of analytes elute at the same time. In mass
spectrometry-based proteomics, (high-pressure) liquid chromatographic separation techniques (HPLC) are methods of choice
to achieve a high degree of separation. In HPLC, peptides are separated on a column. Solved in a pressurized liquid
to achieve a high degree of separation. In HPLC, {term}`peptides` are separated on a column. Solved in a pressurized liquid
(mobile phase) they are pumped through a solid adsorbent material (stationary phase) packet into a capillary column.
Physicochemical properties of each peptide determine how strongly it interacts with the stationary phase. The most
common HPLC technique in proteomics and metabolomics uses reversed-phase chromatography (RPC) columns. RPC employs a
hydrophobic stationary phase like octadecyl (C18), a nonpolar carbon chain bonded to a silica base, and a polar mobile
hydrophobic stationary phase like {term}`octadecyl (C18)`, a nonpolar carbon chain bonded to a silica base, and a polar mobile
phase. Polar molecules interact weakly with the stationary phase and elute earlier, while non-polar molecules are retained.
Interaction can be further modulated by changing the gradient of solvent concentration in the mobile phase over time.
Elution times in LC are inherently prone to variation, for example, due to fluctuations in the flow rate of the mobile
phase or change of column. Retention time shifts between runs may be compensated using computational chromatographic
retention time alignment methods. In the LC-MS setup, the column is directly coupled to the ion source of the mass
retention time alignment methods. In the {term}`LC-MS` setup, the column is directly coupled to the ion source of the mass
spectrometer.

![](images/introduction/introduction_LC.png)

# Mass Spectrometry

MS is an analytical technique used to determine the mass of molecules. In order to achieve highly accurate and sensitive
MS is an analytical technique used to determine the {term}`mass` of molecules. In order to achieve highly accurate and sensitive
mass measurements at the atomic scale, mass spectrometers manipulate charged particles using magnetic and electrostatic
fields.

![](images/introduction/introduction_MS.png)

In a typical mass spectrometer, three principal components can be identified:

- **Ion Source**: A mass spectrometer only handles ions. Thus, charge needs first be transferred to uncharged particles.
The component responsible for the ionization is the ion source. Different types of ion sources and ionization
techniques exist with electrospray ionization (ESI) being currently the most widely used ionization technique for mass
spectrometry-based proteomics.

- **Mass Analyzer**: Most commonly used mass analyzer in proteomics are time-of-flight (TOF) mass analyzers, quadrupole mass
filters, and orbitrap analyzers. In TOF mass analyzers, the ions are accelerated in an electric field. The flight time
of an ion allows calculating the velocity which in turn is used to calculate the mass-to-charge ratio (m/z). Varying
the electric field allows filtering certain mass-to-charge ratios before they enter the detector. In quadrupole mass
filters, ions pass through an oscillating electric field created by four parallel rods. For a particular voltage, only
ions in a certain mass-to-charge range will reach the detector. The orbitrap is an ion trap mass analyzer (and detector)
that traps ions in orbital motion between a barrel-like outer electrode and a spindle-like central electrode allowing
for prolonged mass measurement. As a result of the prolonged mass measurements, a high mass resolution can be achieved.
- **Ion Source**: A mass spectrometer only handles {term}`ions`. Thus, charge needs first be transferred to uncharged
particles. The component responsible for the ionization is the ion source. Different types of ion sources and ionization
techniques exist with {term}`electrospray ionization (ESI)` being currently the most widely used ionization technique
for mass spectrometry-based proteomics.

- **Mass Analyzer**: Most commonly used mass analyzer in proteomics are {term}`time-of-flight (TOF)` mass analyzers,
{term}`quadrupole mass filters`, and {term}`orbitrap analyzers`. In TOF mass analyzers, the ions are accelerated in an electric field.
The flight time of an ion allows calculating the velocity which in turn is used to calculate the mass-to-charge ratio
(m/z). Varying the electric field allows filtering certain mass-to-charge ratios before they enter the detector. In
quadrupole mass filters, ions pass through an oscillating electric field created by four parallel rods. For a
particular voltage, only ions in a certain mass-to-charge range will reach the detector. The orbitrap is an ion trap
mass analyzer (and detector) that traps ions in orbital motion between a barrel-like outer electrode and a spindle-like
central electrode allowing for prolonged mass measurement. As a result of the prolonged mass measurements, a high mass
resolution can be achieved.

- **Detector**: The last component of the mass spectrometer is the detector. It determines the abundance of ions that
passed through the mass analyzer. Ion intensities (a value that relates to its abundance) and the mass-to-charge ratio
are recorded in a mass spectrum.

A sample is measured over the retention time of the chromatography typically resulting in tens of thousands of spectra.
The measurement of one sample is called an MS run and the set of spectra called an MS(1) map or peak map.
The measurement of one sample is called an MS run and the set of spectra called an {term}`MS(1)` map or peak map.

![](images/introduction/spectrum_peakmap.png)

The left image displays spectrum with peaks (m/z and intensity values) and the right image shows spectra stacked in
retention time yielding a peak map.

In proteomics and metabolomics, the MS1 intensity is often used for the quantification of an analyte. Identification
based on the MS1 mass-to-charge and the isotope pattern is highly ambiguous. To improve identification, tandem mass
In proteomics and metabolomics, the MS(1) intensity is often used for the quantification of an analyte. Identification
based on the MS(1) mass-to-charge and the isotope pattern is highly ambiguous. To improve identification, tandem mass
spectrometry (MS/MS) can be applied to assess the analyte substructure. To this end, the precursor ion is isolated and
kinetically fragmented using an inert gas (e.g., Argon). Fragments produced by collision-induced fragmentation (CID) are
stored in an MS2 (or MS/MS) spectrum and provide information that helps to resolve the ambiguities in identification.
kinetically fragmented using an inert gas (e.g., Argon). Fragments produced by {term}`collision-induced dissociation (CID)`
are stored in an MS^2^ (or MS/MS) spectrum and provide information that helps to resolve the ambiguities in identification.
Alternatively, MS/MS spectra can be used for quantification.