Skip to content

[Enhancement] decommission should safety drop be immediately when BE's tablets all in recycled state #14028

@dutyu

Description

@dutyu

Search before asking

  • I had searched in the issues and found no similar issues.

Description

When use decommission cmd to drop BE, some tablets on BE may be recycled, but BE's meta data holds these tablets. Because BE will be droped only when BE's meta data does not containes any tablet, so we always need to wait until trash is expired. So we can check BE's tablets, if all tablets of this BE is in recycled status, we can safety drop the BE immediately.

Solution

No response

Are you willing to submit PR?

  • Yes I am willing to submit a PR!