Skip to content

[Testers Needed] Using non blocking I/O #5

@barry-scott

Description

@barry-scott

I have been looking at the code and noticed that its was using select is an odd way.
The oddity is that the fd is not set O_NONBLOCK.

The end result of using O_NONBLOCK is that the code will report the temperatures as soon the sensor reports them.
Takes 0.386s vs the old code taking 0.558s. Tested with a TEMPer2.

If you are interest in my refactors let me know and I will raise a PR.

My refactor is in barry-scott@772d8c0.

Testers Needed

  • TEMPer 0c45:7401 TEMPerF1.4 I Metal
  • TEMPer 413d:2107 TEMPerGold_V3.1 I Metal
  • TEMPerHUM 413d:2107 TEMPerX_V3.1 I I White plastic
  • TEMPer2 413d:2107 TEMPerX_V3.3 I,E White plastic
  • TEMPer2 1a86:e025 TEMPer2_V3.7 I,E White plastic with red button
  • TEMPer1F 413d:2107 TEMPerX_V3.3 E White plastic
  • TEMPerX232 1a86:5523 TEMPerX232_V2.0 I,E I White plastic
  • TEMPer1V1.1 0c45:7401 TEMPer1F1.1Per1F E Metal

Tests Passing

  • TEMPer 0c45:7401 TEMPerF1.4 I Metal
  • TEMPer 413d:2107 TEMPerGold_V3.1 I Metal
  • TEMPerHUM 413d:2107 TEMPerX_V3.1 I I White plastic
  • TEMPer2 413d:2107 TEMPerX_V3.3 I,E White plastic
  • TEMPer2 1a86:e025 TEMPer2_V3.7 I,E White plastic with red button
  • TEMPer1F 413d:2107 TEMPerX_V3.3 E White plastic
  • TEMPerX232 1a86:5523 TEMPerX232_V2.0 I,E I White plastic
  • TEMPer1V1.1 0c45:7401 TEMPer1F1.1Per1F E Metal

Metadata

Metadata

Assignees

No one assigned

    Labels

    enhancementNew feature or requesthelp wantedExtra attention is needed

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests