Releases: harp-tech/device.olfactometer
fw2.3-harp1.15
What's Changed
- Update core to 1.14 by @artursilva0 in #31
- update device.yml fw version by @artursilva0 in #33
- Updated to atxmega core 1.15 by @artursilva0 in #34
Full Changelog: app1.2.2...fw2.3-harp1.15
app 1.2.2
What's Changed
- Add compatibility table to readme by @artursilva0 in #29
- Bugfix/app fixes by @MicBoucinha in #32
Full Changelog: app1.2.1...app1.2.2
App specific changes
- Some registers only available on HW > 2.0 are now properly hidden when connecting to different HW versions.
- Usage of Set and Clear buttons for the available DigitalOutputs
- DigitalOutputState is updated automatically
Binaries are available for Windows, macOS and Linux for both x64 and arm64.
Please see the Assets below and choose the appropriate version.
fw2.2-harp1.14
What's Changed
- Add compatibility table to readme by @artursilva0 in #29
- Bugfix/app fixes by @MicBoucinha in #32
- Update core to 1.14 by @artursilva0 in #31
- update device.yml fw version by @artursilva0 in #33
Full Changelog: app1.2.1...fw2.2-harp1.14
app1.2.1
What's Changed
- App 1.2.1 - bug fixes by @MicBoucinha in #30
Full Changelog: fw2.1-harp1.14-preview3...app1.2.1
App specific changes
- Fix issue with Channel 3 Range combobox
- Windows Installer now shows properly under Installed Apps under Windows 11
Warning
From v1.2 onward, this application only works for Olfactometers with firmware 2.0 or up. If you have an older version of firmware, please update the firmware or download an earlier version of the app.
Binaries are available for Windows, MacOS (Intel and Apple Silicon) and Linux.
Please see the Assets below and choose the appropriate version.
fw2.1-harp1.14-preview3
What's Changed
- fix check valves state bug and update fw version by @artursilva0 in #28
Full Changelog: app1.2...fw2.1-harp1.14-preview3
app1.2
What's Changed
- Update device.yml fw version by @artursilva0 in #17
- Ensure
ChannelsTargetFlowregister handles 0-values properly by @artursilva0 in #20 - Update fw 2.0 by @artursilva0 in #24
- Interface 0.3.0 by @artursilva0 in #25
- Feature/app update by @MicBoucinha in #27
Full Changelog: app1.1...app1.2
App specific changes
- Usage of the most recent Harp interface for the Olfactometer (0.3.0)
- Update to the latest .NET LTS (8.0) and Avalonia version (11.2.6)
Warning
This application version only works for Olfactometers with firmware 2.0 or up. If you have an older version of firmware, please update the firmware or download an earlier version of the app.
Binaries are available for Windows, MacOS (Intel and Apple Silicon) and Linux.
Please see the Assets below and choose the appropriate version.
fw2.0-harp1.14-preview3
What's Changed
- Update fw 2.0 by @artursilva0 in #24
- Interface 0.3.0 by @artursilva0 in #25
Full Changelog: fw1.5-harp1.13...fw2.0-harp1.14-preview3
fw1.5-harp1.13
What's Changed
- Update device.yml fw version by @artursilva0 in #17
- Ensure
ChannelsTargetFlowregister handles 0-values properly by @artursilva0 in #20
Full Changelog: app1.1...fw1.5-harp1.13
app1.1
fw1.4-harp1.13
What's Changed
- Update temp correction for channel 3 - 100 by @artursilva0 in #15
- Include device metadata file as embedded resource by @glopesdev in #14
- Code clean up and reduce main routine execution time by @artursilva0 in #16
Full Changelog: fw1.3-harp1.13...fw1.4-harp1.13