CyberPower CP1500EPFCLCD (European version of the CP1500PFCLCD): http://www.cyberpower-eu.com/products/ups_systems/pfc-sinewave/cp1500epfclcd.htm
Shutdown sequence tested successfully via USB using NUT 2.7.3.
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 2640
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 24.0
battery.voltage.nominal: 24
device.mfr: CP1500EPFCLCD
device.model: CRJB103.551
device.serial: CPS
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: no
driver.version: 2.7.3
driver.version.data: CyberPower HID 0.4
driver.version.internal: 0.39
input.transfer.high: 260
input.transfer.low: 170
input.voltage: 237.0
input.voltage.nominal: 230
output.voltage: 269.0
ups.beeper.status: disabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 19
ups.mfr: CP1500EPFCLCD
ups.model: CRJB103.551
ups.productid: 0501
ups.realpower.nominal: 900
ups.serial: CPS
ups.status: OL
ups.test.result: No test initiated
ups.timer.shutdown: -60
ups.timer.start: -60
ups.vendorid: 0764
upsrw output:
[battery.charge.low]
Remaining battery level when UPS switches to LB (percent)
Type: STRING
Maximum length: 10
Value: 10
[battery.runtime.low]
Remaining battery runtime when UPS switches to LB (seconds)
Type: STRING
Maximum length: 10
Value: 300
[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 260
[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 170
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: STRING
Maximum length: 10
Value: 30
upscmd -l output:
Instant commands supported on UPS [cyberpower]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
load.on - Turn on the load immediately
load.on.delay - Turn on the load with a delay (seconds)
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test
CyberPower CP1500EPFCLCD (European version of the CP1500PFCLCD): http://www.cyberpower-eu.com/products/ups_systems/pfc-sinewave/cp1500epfclcd.htm
Shutdown sequence tested successfully via USB using NUT 2.7.3.