Hello,
I'm trying to get my APC Back-UPS pro 900 connected but it seems to fail to show any value's.
The following screenshot is what i see:

These are the variables coming from the List UPS Variables:
APC Back-UPS 900Pro (Unknown/Unknown/Unknown) battery.charge (Description unavailable) : 100 battery.charge.low (Description unavailable) : 50 battery.charge.warning (Description unavailable) : 50 battery.date (Description unavailable) : 2001/09/25 battery.mfr.date (Description unavailable) : 2024/06/03 battery.runtime (Description unavailable) : 2300 battery.runtime.low (Description unavailable) : 300 battery.type (Description unavailable) : PbAc battery.voltage (Description unavailable) : 27.1 battery.voltage.nominal (Description unavailable) : 24.0 device.mfr (Description unavailable) : American Power Conversion device.model (Description unavailable) : Back-UPS RS 900G device.serial (Description unavailable) : 3B1231X30657 device.type (Description unavailable) : ups driver.name (Description unavailable) : usbhid-ups driver.parameter.pollfreq (Description unavailable) : 30 driver.parameter.pollinterval (Description unavailable) : 15 driver.parameter.port (Description unavailable) : auto driver.parameter.productid (Description unavailable) : 0002 driver.parameter.serial (Description unavailable) : 3B1231X30657 driver.parameter.synchronous (Description unavailable) : auto driver.parameter.vendorid (Description unavailable) : 051D driver.version (Description unavailable) : 2.8.0 driver.version.data (Description unavailable) : APC HID 0.98 driver.version.internal (Description unavailable) : 0.47 driver.version.usb (Description unavailable) : libusb-1.0.26 (API: 0x1000109) input.sensitivity (Description unavailable) : medium input.transfer.high (Description unavailable) : 294 input.transfer.low (Description unavailable) : 176 input.voltage (Description unavailable) : 233.0 input.voltage.nominal (Description unavailable) : 230 ups.beeper.status (Description unavailable) : disabled ups.delay.shutdown (Description unavailable) : 20 ups.firmware (Description unavailable) : 879.L4 .I ups.firmware.aux (Description unavailable) : L4 ups.load (Description unavailable) : 26 ups.mfr (Description unavailable) : American Power Conversion ups.mfr.date (Description unavailable) : 2012/08/04 ups.model (Description unavailable) : Back-UPS RS 900G ups.productid (Description unavailable) : 0002 ups.realpower.nominal (Description unavailable) : 540 ups.serial (Description unavailable) : 3B1231X30657 ups.status (Description unavailable) : OL ups.test.result (Description unavailable) : No test initiated ups.timer.reboot (Description unavailable) : 0 ups.timer.shutdown (Description unavailable) : -1 ups.vendorid (Description unavailable) : 051d
This is the debug log:
`
7-11-2024 21:32:37 [12464, WinNUT]: Battery Status => Discharging
7-11-2024 21:32:38 [12464, UPS_Device]: Enter Retrieve_UPS_Datas
7-11-2024 21:32:38 [12464, UPS_Device]: battery.charge is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving battery.charge
7-11-2024 21:32:38 [12464, UPS_Device]: battery.voltage is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving battery.voltage
7-11-2024 21:32:38 [12464, UPS_Device]: battery.runtime is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving battery.runtime
7-11-2024 21:32:38 [12464, UPS_Device]: input.frequency is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving input.frequency
7-11-2024 21:32:38 [12464, UPS_Device]: input.voltage is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving input.voltage
7-11-2024 21:32:38 [12464, UPS_Device]: output.voltage is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving output.voltage
7-11-2024 21:32:38 [12464, UPS_Device]: ups.load is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving ups.load
7-11-2024 21:32:38 [12464, UPS_Device]: Unable to calculate UPS Batt_Charge: Batt_Voltage (-1) out of range.
7-11-2024 21:32:38 [12464, UPS_Device]: Unable to calculate battery runtime, missing UPS variables.
7-11-2024 21:32:38 [12464, UPS_Device]: Output_Voltage: -1, Batt_Voltage: -1, Batt_Capacity: -1, Batt_Charge: -1
7-11-2024 21:32:38 [12464, UPS_Device]: ups.status is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving ups.status
7-11-2024 21:32:38 [12464, UPS_Device]: UPS statuses have not changed since last update, skipping.
7-11-2024 21:32:38 [12464, WinNUT]: Updating UPS data for Form.
7-11-2024 21:32:38 [12464, WinNUT]: Updating battery icons based on charge percent: -1%
7-11-2024 21:32:38 [12464, WinNUT]: Update Dial
7-11-2024 21:32:38 [12464, WinNUT]: Update Icon
7-11-2024 21:32:38 [12464, WinNUT]: NotifyIcon Text =>
WinNUT Client - 2.3
Connected
On Battery (-1%)
7-11-2024 21:32:38 [12464, WinNUT]: Battery Status => Discharging
7-11-2024 21:32:38 [12464, Pref_Gui]: User clicked ViewLog button.
7-11-2024 21:32:38 [12464, Pref_Gui]: Opened UI window to log location.
`
Can anyone tell me what i'm doing wrong?
Hello,
I'm trying to get my APC Back-UPS pro 900 connected but it seems to fail to show any value's.
The following screenshot is what i see:
These are the variables coming from the List UPS Variables:
APC Back-UPS 900Pro (Unknown/Unknown/Unknown) battery.charge (Description unavailable) : 100 battery.charge.low (Description unavailable) : 50 battery.charge.warning (Description unavailable) : 50 battery.date (Description unavailable) : 2001/09/25 battery.mfr.date (Description unavailable) : 2024/06/03 battery.runtime (Description unavailable) : 2300 battery.runtime.low (Description unavailable) : 300 battery.type (Description unavailable) : PbAc battery.voltage (Description unavailable) : 27.1 battery.voltage.nominal (Description unavailable) : 24.0 device.mfr (Description unavailable) : American Power Conversion device.model (Description unavailable) : Back-UPS RS 900G device.serial (Description unavailable) : 3B1231X30657 device.type (Description unavailable) : ups driver.name (Description unavailable) : usbhid-ups driver.parameter.pollfreq (Description unavailable) : 30 driver.parameter.pollinterval (Description unavailable) : 15 driver.parameter.port (Description unavailable) : auto driver.parameter.productid (Description unavailable) : 0002 driver.parameter.serial (Description unavailable) : 3B1231X30657 driver.parameter.synchronous (Description unavailable) : auto driver.parameter.vendorid (Description unavailable) : 051D driver.version (Description unavailable) : 2.8.0 driver.version.data (Description unavailable) : APC HID 0.98 driver.version.internal (Description unavailable) : 0.47 driver.version.usb (Description unavailable) : libusb-1.0.26 (API: 0x1000109) input.sensitivity (Description unavailable) : medium input.transfer.high (Description unavailable) : 294 input.transfer.low (Description unavailable) : 176 input.voltage (Description unavailable) : 233.0 input.voltage.nominal (Description unavailable) : 230 ups.beeper.status (Description unavailable) : disabled ups.delay.shutdown (Description unavailable) : 20 ups.firmware (Description unavailable) : 879.L4 .I ups.firmware.aux (Description unavailable) : L4 ups.load (Description unavailable) : 26 ups.mfr (Description unavailable) : American Power Conversion ups.mfr.date (Description unavailable) : 2012/08/04 ups.model (Description unavailable) : Back-UPS RS 900G ups.productid (Description unavailable) : 0002 ups.realpower.nominal (Description unavailable) : 540 ups.serial (Description unavailable) : 3B1231X30657 ups.status (Description unavailable) : OL ups.test.result (Description unavailable) : No test initiated ups.timer.reboot (Description unavailable) : 0 ups.timer.shutdown (Description unavailable) : -1 ups.vendorid (Description unavailable) : 051dThis is the debug log:
`
7-11-2024 21:32:37 [12464, WinNUT]: Battery Status => Discharging
7-11-2024 21:32:38 [12464, UPS_Device]: Enter Retrieve_UPS_Datas
7-11-2024 21:32:38 [12464, UPS_Device]: battery.charge is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving battery.charge
7-11-2024 21:32:38 [12464, UPS_Device]: battery.voltage is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving battery.voltage
7-11-2024 21:32:38 [12464, UPS_Device]: battery.runtime is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving battery.runtime
7-11-2024 21:32:38 [12464, UPS_Device]: input.frequency is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving input.frequency
7-11-2024 21:32:38 [12464, UPS_Device]: input.voltage is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving input.voltage
7-11-2024 21:32:38 [12464, UPS_Device]: output.voltage is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving output.voltage
7-11-2024 21:32:38 [12464, UPS_Device]: ups.load is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving ups.load
7-11-2024 21:32:38 [12464, UPS_Device]: Unable to calculate UPS Batt_Charge: Batt_Voltage (-1) out of range.
7-11-2024 21:32:38 [12464, UPS_Device]: Unable to calculate battery runtime, missing UPS variables.
7-11-2024 21:32:38 [12464, UPS_Device]: Output_Voltage: -1, Batt_Voltage: -1, Batt_Capacity: -1, Batt_Charge: -1
7-11-2024 21:32:38 [12464, UPS_Device]: ups.status is not supported by server.
7-11-2024 21:32:38 [12464, UPS_Device]: Apply Fallback Value when retrieving ups.status
7-11-2024 21:32:38 [12464, UPS_Device]: UPS statuses have not changed since last update, skipping.
7-11-2024 21:32:38 [12464, WinNUT]: Updating UPS data for Form.
7-11-2024 21:32:38 [12464, WinNUT]: Updating battery icons based on charge percent: -1%
7-11-2024 21:32:38 [12464, WinNUT]: Update Dial
7-11-2024 21:32:38 [12464, WinNUT]: Update Icon
7-11-2024 21:32:38 [12464, WinNUT]: NotifyIcon Text =>
WinNUT Client - 2.3
Connected
On Battery (-1%)
7-11-2024 21:32:38 [12464, WinNUT]: Battery Status => Discharging
7-11-2024 21:32:38 [12464, Pref_Gui]: User clicked ViewLog button.
7-11-2024 21:32:38 [12464, Pref_Gui]: Opened UI window to log location.
`
Can anyone tell me what i'm doing wrong?