In GitLab by @schislet on Mar 25, 2021, 12:03
Summary
For LTS materials fcu = copper fraction of the cable conductor. For HTS materials fcu = copper fraction of the cable conductor NOT including the copper within the REBCO tapes themselves.
We should introduce a second variable for HTS, fcu_HTS, to make this distinction more clear.
@mkovari @skahn
Checklist
After implementing issue do the following
In GitLab by @schislet on Mar 25, 2021, 12:03
Summary
For LTS materials fcu = copper fraction of the cable conductor. For HTS materials fcu = copper fraction of the cable conductor NOT including the copper within the REBCO tapes themselves.
We should introduce a second variable for HTS, fcu_HTS, to make this distinction more clear.
@mkovari @skahn
Checklist
After implementing issue do the following