Description

Adds a warning if the TF or centrepost magnet current ratios are over 70%. This is to warn the user of engineering infeasibility.

Checklist

I confirm that I have completed the following checks:

  • I have justified any large differences in the regression tests caused by this pull request in the comments.
  • I have added new tests where appropriate for the changes I have made.
  • If I have had to change any existing unit or integration tests, I have justified this change in the pull request comments.
  • If I have made documentation changes, I have checked they render correctly.
  • I have added documentation for my change, if appropriate.

@j-a-foster j-a-foster requested a review from chris-ashe August 23, 2024 08:25
@j-a-foster j-a-foster linked an issue Aug 23, 2024 that may be closed by this pull request
4 tasks
Comment thread documentation/proc-pages/eng-models/central-solenoid.md Outdated
Comment thread documentation/proc-pages/eng-models/tf-coil.md Outdated
@j-a-foster j-a-foster merged commit 72776cb into main Aug 23, 2024