Updating TPC gain calibration constants #718

@sungbinoh

Description

@sungbinoh

I'm submitting a ...

  • bug report
  • feature request
  • [v] Task

Checklist

  • [V ] I've added at least 1 label under Labels
  • [ V] Assigned a reviewer under Assignees

Expected Behavior

I would like to update TPC gain calibration constants.
It is for improving agreement in Chi2 PID variables between data and MC.

Current Behavior

Data and MC show discrepancy in peak positions of chi2 PID variables distributions.

Possible Solution (optional)

Updating calibration constants to values measured using the v10 samples..

How to reproduce

N/A.
Please have a look to SBN-doc-40714.